Measurements

Room size

The chart assumes 8 ft. Taller rooms scale up in proportion.

Sun exposure

Adds 600 BTU/h for each person beyond two.

Your estimate

Choose an 8,000 BTU air conditioner.

8,000 BTU/h needed for 320 sq ft, rounded up to the next standard size.

Floor area
320 sq ft
Chart capacity for this areaENERGY STAR room AC chart
8,000 BTU/h
Cooling needed
8,000 BTU/h
Same in tons1 ton = 12,000 BTU/h
0.67 tons
Same in kilowatts
2.34 kW
Standard size to buy2.3 kW — next common window / mini-split size up
8,000 BTU/h
  • This is the ENERGY STAR rule of thumb for a single room, not a Manual J load calculation. Big west-facing windows, poor insulation or a hot attic above can push the real need higher.

Next step

Estimate running cost

Check the unit's rated watts or yearly kWh on its EnergyGuide label, then price it at your rate.

Electricity cost calculator

Also useful

Size heat for the same room

Heating depends on how cold it gets outside and how well the room is insulated.

Heater size calculator

How to measure

  1. Measure the room's length and width wall to wall. For an open plan, measure the whole area the unit has to cool — it can't stop at an imaginary line.
  2. Measure ceiling height. The chart assumes 8 ft; taller rooms hold more air and need more capacity.
  3. Judge sun exposure honestly: 'very sunny' means large south- or west-facing windows with direct afternoon sun; 'heavily shaded' means trees or buildings block most of it.
  4. Count the people who are regularly in the room at the same time, and turn on the kitchen option if the unit cools a cooking area.

How the ac btu calculation works

Base         = ENERGY STAR chart capacity for the floor area
Adjusted     = base × max(1, ceiling ÷ 8 ft) × sun factor
Sun factor   = 0.9 heavily shaded · 1.0 normal · 1.1 very sunny
Total BTU/h  = adjusted + 600 × (people − 2) + 4,000 if kitchen
Buy          = next standard size ≥ total

ENERGY STAR publishes a room air conditioner chart that maps floor area to capacity — 5,000 BTU for up to 150 sq ft, 8,000 BTU for 300–350 sq ft, 12,000 BTU for 450–550 sq ft and so on up to 2,500 sq ft. The calculator looks up your area in that chart.

The same guidance adds 10% for very sunny rooms, takes 10% off for heavily shaded ones, adds 600 BTU/h for each regular occupant beyond two, and adds 4,000 BTU/h for a kitchen. We also scale the chart value up in proportion for ceilings above 8 ft, since there is more air to cool.

Window units and ductless heads come in set sizes, so the result rounds up to the next one: 5,000, 6,000, 8,000, 10,000, 12,000, 14,000, 18,000, 24,000, 30,000 or 36,000 BTU.

Worked example

An open kitchen and family room, 20 × 20 ft with a 10 ft ceiling, very sunny, used by four people.

  1. Area: 20 × 20 = 400 sq ft → chart capacity 10,000 BTU/h (400–450 sq ft band)
  2. Ceiling: 10 ÷ 8 = 1.25 → 10,000 × 1.25 = 12,500 BTU/h
  3. Very sunny: 12,500 × 1.1 = 13,750 BTU/h
  4. Two extra people: 2 × 600 = 1,200 BTU/h
  5. Kitchen: + 4,000 BTU/h → total 18,950 BTU/h (1.58 tons)

Choose a 24,000 BTU unit — 18,000 BTU would fall short. A 2-ton mini-split, or two smaller units, would also suit a space this shape.

Reading your result

The highlighted size is the smallest standard unit that meets the estimate. Don't go several sizes bigger 'to be safe': an oversized unit cools quickly, shuts off before it removes humidity, and leaves the room cold and clammy.

The tons and kilowatt figures help compare against mini-split and heat pump spec sheets, which often list capacity that way. One ton is 12,000 BTU/h.

If the total lands just above a standard size, look at what pushed it there — closing blinds on a sunny wall can be worth 10%.

Assumptions

  • Average insulation and windows, and a room that isn't under a hot, unvented attic. Older homes with little insulation may need a size up.
  • The chart is for a single room cooled by one unit. It is not a whole-house central air sizing method.
  • Ceiling height scaling above 8 ft is our simple proportional adjustment, not part of the ENERGY STAR chart.

Unit conversions use exact definitions (1 in = 25.4 mm, 1 US gal = 3.785 L). See the calculation methodology for rounding rules.

When to call a professional

  • For central air, a heat pump or anything over about 2,500 sq ft, ask an HVAC contractor for a Manual J load calculation. It accounts for window area, orientation, insulation and your climate.
  • Window units over about 12,000 BTU and most mini-splits need a dedicated circuit, often 240 V. Have an electrician check before you buy.

Frequently asked questions

What size air conditioner do I need for a 12 × 12 room?

144 sq ft falls in the 100–150 sq ft band, so 5,000 BTU. Go to 6,000 BTU if the room is very sunny or regularly has more than two people in it.

How many square feet does a 10,000 BTU air conditioner cool?

About 400–450 sq ft under normal conditions with an 8 ft ceiling. A sunny room, high ceiling or kitchen lowers that.

Is a bigger air conditioner better?

No. An oversized unit short-cycles: it hits the set temperature fast and shuts off before pulling moisture out of the air, so the room feels damp. It also costs more and uses more power for no benefit.

How many BTU is a ton of air conditioning?

12,000 BTU per hour. A 24,000 BTU unit is 2 tons; a 36,000 BTU unit is 3 tons.

More energy & hvac calculators