Deck Board Spacing: Gaps for Composite & Treated Wood
Trex and TimberTech side, end and wall gaps by installation temperature, plus AWC and SFPA spacing for wet and kiln-dried treated boards.
Updated October 18, 2026
The short answer
For composite decking, use the board maker’s numbers: Trex requires at least 3/16 in (5 mm) between boards and TimberTech requires 1/8–3/16 in. For wood, the American Wood Council’s deck guide says to space boards approximately 1/8 in apart. Wet pressure-treated pine is the exception. It shrinks as it dries, so the Southern Forest Products Association (SFPA) sets the gap from the width you measure when you install it.
End-to-end gaps on composite boards depend on the temperature on the day you install, because the boards grow and shrink in length with heat. Wood decking changes width as it gains and loses moisture.
Side gaps between boards
| Board | Side-to-side gap | Source |
|---|---|---|
| Trex composite | 3/16 in (5 mm) minimum, 1/2 in (13 mm) maximum | 2026 Trex Decking Installation Guide |
| TimberTech composite | 1/8 in minimum to 3/16 in maximum | TimberTech Decking Installation Guide (rev. 09/23) |
| Wood decking | About 1/8 in | AWC Prescriptive Residential Wood Deck Construction Guide (DCA 6) |
| Treated Southern Pine 2×6 and 5/4×6 | 0 to 1/4 in, set by the board’s width at installation | SFPA, Southern Pine Decks and Porches |
Trex says its 3/16 in minimum applies whether you install in hot or cold weather. It recommends 3/8 in (10 mm) in heavily wooded areas, and widening the gaps to 3/8 in is also one of its ways to improve airflow under a deck.
End gaps and installation temperature
Composite boards get longer when they warm up. A board installed on a cold day is at its shortest, so it needs a wider gap at its ends. A board installed on a hot day is near its longest, so it needs less.
Trex (end-to-end and end-to-width gaps):
| Temperature at installation | End-to-end gap | Gap at a wall or solid object |
|---|---|---|
| Above 40°F (4.5°C) | 1/8 in (3 mm) | 1/4 in (6 mm) |
| Below 40°F (4.5°C) | 3/16 in (5 mm) | 1/2 in (13 mm) |
TimberTech (butt joints):
| Temperature at installation | Butt-joint gap |
|---|---|
| 32°F and below | 3/16 in |
| 33°F to 74°F | 1/8 in |
| 75°F and above | 1/32 in |
TimberTech also warns that boards cut on a hot afternoon and left out overnight can shrink by morning. Fasten boards as soon as you can after cutting them. Trex publishes a separate metric table for Canada, and both makers revise their guides, so check the current guide for your product line before you start.
The gap at the house and posts
Composite decking must not be butted tight against the house, a post or any other fixed object:
- Trex: 1/4–1/2 in (6–13 mm) where decking meets a wall, set by the temperature at installation (table above). Fascia boards follow the same gapping rules.
- TimberTech: at least 3/16 in where the boards meet any adjoining structure or post.
The wood-deck guides we used (AWC and SFPA) don’t give a separate gap for wood decking at a wall.
Wood boards: wet vs. kiln-dried
Treated lumber that isn’t re-dried after treatment is sold wet, and it shrinks across its width as it dries. Boards that were kiln-dried after treatment (KDAT) or marked DRY on the end tag or stamp have already done most of that shrinking.
The SFPA’s spacing table for treated Southern Pine 2×6 and 5/4×6 decking keys the gap to the board’s actual width when you install it. A dry board of this size is 5½ in wide:
| Measured width at installation | Spacing (min–max) |
|---|---|
| 5½ in (wet or dry) | 1/8–1/4 in |
| 5⅝ in (wet) | 1/16–1/8 in |
| 5¾ in (wet) | No space |
| More than 5¾ in (wet) | Let the boards dry before installing |
Measure a few boards from the stack with a tape. If they are swollen to 5¾ in, laying them tight leaves a gap once they shrink back toward 5½ in. KDAT boards are already near 5½ in, so they need the gap from the start.
Hidden fasteners set the gap
With grooved boards and hidden clips, the clip sits between the boards and sets the side gap. Trex says so for its Hideaway fasteners: the fastener’s placement sets the gap. End gaps still follow the temperature table.
Worked example: rows on a 12 ft deck
Each row takes one board width plus one gap. On a deck 12 ft (144 in) out from the house, with 5½ in boards:
No gap 144 ÷ 5.5 = 26.2 → 27 rows 1/8 in gap 144 ÷ 5.625 = 25.6 → 26 rows 3/16 in gap 144 ÷ 5.6875 = 25.3 → 26 rows 1/4 in gap 144 ÷ 5.75 = 25.04 → 26 rows
Every gap from 1/8 in to 1/4 in gives 26 rows here. The last row is ripped to fit, so a different gap changes its width, not the board count. Laying the same boards tight adds a 27th row.
In metric
The figures above are in US units, as the manufacturers and standards give them. Here they are in metric, converted with the same factors the calculators use. Switch any calculator to m · cm to work in metric from the start.
| Figure in this guide | US | Metric |
|---|---|---|
| Gap, 1/8 in | 0.125 inches | ≈ 3.2 mm |
| Gap, 3/16 in | 0.1875 inches | ≈ 4.8 mm |
| Deck width, 12 ft | 12 feet | ≈ 3.66 m |
Calculate it for your project
The Decking Calculator takes your board width and gap and counts rows, boards, joists and screws or hidden clips. Its default gap is 3/16 in (5 mm), Trex’s minimum. Change it to match your boards. Staining wood boards? The Deck Stain Calculator estimates the gallons. Planning the whole job? Use the deck planner.